- Siphon protects against overpressure in the boiler
- Stainless steel electrodes
- Automatic draining system with 42 mm diameter
- Automatic boiler cleaning system
- Boiler cylinder and polymeric parts in self-extinguishing material
- Protection against water escaping on the steam side
- No mechanical obstructions on the steam side and drain side
- Mechanical parts designed to simplify use and maintenance
Ideal in the following applications
| Models | K3-230 | K10-230 | K20-230 | K5-400 | K10-400 | K20-400 | K30-400 | K40-400 | K60-400 | |
|---|---|---|---|---|---|---|---|---|---|---|
| STEAM PRODUCTION | ||||||||||
| Production capacity | [Kg/h] | 3 | 10 | 20 | 5 | 10 | 20 | 30 | 40 | 60 |
| Maximum pressure | [Mpa-mm H2O/bar] | 0,0020-200 | ||||||||
| Pipe connection external diameter | [mm] | 40 | ||||||||
| STEAM DISTRIBUTION | ||||||||||
| Number of linear distributors that can be connected | [n] | 1 | 1 | 2 | 1 | 1 | 1 | 1 | 2 | 2 |
| Number of blowers that can be connected | [n] | 1 | 1 | / | 1 | 1 | / | / | / | / |
| ELECTRICAL PROPERTIES | ||||||||||
| Power consumption | [kW] | 2.5 | 7.5 | 15 | 4 | 7.5 | 15 | 22.5 | 30 | 45 |
| Power supply | [Vac, Hz] | 230, 50 | 400, 50 | |||||||
| Phases | [n] | 1 | 3 | 3 | 2 | 3 | 3 | 3 | 3 | 3 |
| Current per phase | [A] | 10 | 20 | 40 | 10 | 10 | 20 | 30 | 40 | 60 |
| WATER PROPERTIES | ||||||||||
| Inlet water quality | Complies with microbiological standards for drinking water established by regulations in force where installed. Partially demineralised water may be used | |||||||||
| Inlet water conductivity | μS*cm | 70…1250 | ||||||||
| Inlet water hardness | °f | 5...50 | ||||||||
| Inlet water pressure | [MPa/bar] | 0,2...1/2...10 | ||||||||
| Inlet water connection | --- | 3/4"GAS | ||||||||
| Water drain external dimensions | [mm] | 42 | ||||||||
| GENERAL CHARACTERISTICS | ||||||||||
| Dimensions | (WxHxD [mm]) | 370x610x210 | 610x610x210 | |||||||
| Weight | [kg] | 15 | 25 | |||||||
| Hydraulic unit IP protection | --- | 20 | ||||||||
| CONTROL | ||||||||||
| Type of controller | --- | built-in | ||||||||
| Command signal | --- | proportional (0-10 V) or ON-OFF | ||||||||
| Linear steam distributors | |
| EHSD040 | linear steam distrubutor 400 mm long |
| EHSD060 | linear steam distrubutor 600 mm long |
| EHSD080 | linear steam distrubutor 800 mm long |
| EHSD100 | linear steam distrubutor 1.000 mm long |
| EHSD130 | linear steam distrubutor 1.300 mm long |
| EHSD160 | linear steam distrubutor 1.600 mm long |
| EHSD200 | linear steam distrubutor 2.000 mm long |
| EHSDSP0 | linear steam distrubutor, measure on request |
| Steam blowers | |
| EHSR0107 | steam blower |
| Drainage tanks | |
| VI | drainage tank |
| Special steam piping | |
| TV | special steam piping that connects the humidifier and distributor (per meter) |
| Flexible hoses to load water | |
| 31000048 | flexible hose ¾ " GAS female that connects the mains water and solenoid valve to load water |
| Boilers | |
| BKT3 | boiler for KT3 and KT5 |
| BKT10 | boiler for KT10 |
| BKT20 | boiler for KT20 and KT40 |
| BKT30 | boiler for KT30 and KT60 |